冷卻塔美化煙囪工程
焊接管道時(shí),應(yīng)防止管道中出現(xiàn)通流。煙囪美化有特殊要求的除外。每條焊縫應(yīng)一次焊完。
After welding, the slag on the weld surface and the splash on both sides should be cleaned up. The installation of steel pipes shall meet the following requirements. Before installation, the dirt and corrosion on the inner and outer walls of pipes and fittings shall be cleaned. When the pipeline installation is intermittent, the open nozzle should be closed in time;
The bending radius of the pipe bend, hot bending should not be less than the pipe outer diameter times and cold bending should not be less than times; Welding elbow should not be less than times; Stamping elbow should not be less than times. The difference between the big outside diameter and the small outside diameter of the elbow should not be greater than/of the outside diameter of the pipeline, and the wall thinning rate should not be greater than%; Water cooling tower beautification chimney project
冷熱水管道與支吊架之間應(yīng)有保溫墊(承載強(qiáng)度能滿足管道重量的不燃性硬質(zhì)保溫材料或經(jīng)過防腐處理的木墊,其厚度不應(yīng)小于保溫層的厚度,寬度應(yīng)與支吊架一致。墊片表面應(yīng)平整,墊片結(jié)合面的縫隙應(yīng)填滿;冷卻塔美化煙囪工程
管道安裝的坐標(biāo)標(biāo)高和縱橫曲率應(yīng)符合表中的規(guī)定。暗管在吊架中的位置應(yīng)正確,無明顯偏差。
插入式儀表管道安裝的允許偏差和檢驗(yàn)方法:冷卻塔美化煙囪工程。
支架制造和安裝
固定在建筑結(jié)構(gòu)上的管道支吊架不應(yīng)影響結(jié)構(gòu)的安全。管道穿過煙囪或樓板處應(yīng)設(shè)置鋼套管,管道接口不得置于套管內(nèi)。鋼套管應(yīng)與煙囪飾面或樓板底部平齊,上部應(yīng)高于樓板地面,且不得用作管道支架。
根據(jù)設(shè)計(jì)要求,空調(diào)冷凝水支管安裝排水坡度為i=除非另有標(biāo)注,冷卻塔煙囪美化工程的煙囪美化應(yīng)嚴(yán)格按照要求進(jìn)行。冷卻塔美化煙囪工程
由于空調(diào)水系統(tǒng)管道內(nèi)部是與室溫有溫差的介質(zhì),運(yùn)行時(shí)管道會(huì)收縮(制冷循環(huán)管道)或膨脹(冬季供暖管道),所以必須增加相應(yīng)的措施。補(bǔ)償器的補(bǔ)償量和安裝位置必須符合設(shè)計(jì)和產(chǎn)品技術(shù)文件的要求,并應(yīng)根據(jù)設(shè)計(jì)計(jì)算的補(bǔ)償量進(jìn)行預(yù)拉伸或預(yù)壓縮。
配備補(bǔ)償器(膨脹管道應(yīng)配備固定支架,其結(jié)構(gòu)形式和固定位置應(yīng)符合設(shè)計(jì)要求,并在補(bǔ)償器預(yù)拉伸(或預(yù)壓)前固定;導(dǎo)軌支架的設(shè)置應(yīng)符合所安裝產(chǎn)品技術(shù)文件的要求。
沒有補(bǔ)償器(擴(kuò)展管道應(yīng)配備滑動(dòng)支架(框架))。
金屬管道支吊架的類型、位置、間距和標(biāo)高應(yīng)符合設(shè)計(jì)或相關(guān)技術(shù)標(biāo)準(zhǔn)的要求。當(dāng)設(shè)計(jì)無規(guī)定時(shí),應(yīng)符合下列規(guī)定:冷卻塔美化煙囪工程
支吊架的安裝應(yīng)平整牢固,并與管道緊密接觸。管道和設(shè)備的連接處應(yīng)設(shè)置獨(dú)立的支吊架;
冷(熱介質(zhì))水冷卻系統(tǒng)管道間內(nèi)主管道的支吊架宜采用承重防搖管架;與設(shè)備連接的管架應(yīng)有減振措施。當(dāng)水平支管的管架采用單桿吊架時(shí),應(yīng)在管道起點(diǎn)和閥門三通彎頭長(zhǎng)度上每隔一定距離設(shè)置一個(gè)承重防搖吊架;
對(duì)于無熱位移的管道吊架,吊桿應(yīng)垂直安裝;有熱位移時(shí),吊桿安裝方向應(yīng)與熱脹(或冷縮)方向相反,偏移量應(yīng)通過計(jì)算確定;冷卻塔美化煙囪工程
滑動(dòng)支座的滑動(dòng)面應(yīng)干凈、光滑,其安裝位置應(yīng)從支承面的中心向相反方向偏移/移位或符合設(shè)計(jì)文件的要求;
豎井內(nèi)的立管,每隔~層應(yīng)設(shè)置導(dǎo)向支架。當(dāng)建筑結(jié)構(gòu)荷載允許時(shí),水平安裝管道的支吊架間距應(yīng)符合下表的規(guī)定;冷卻塔美化煙囪工程